4 votes

Answer:

a

Step-by-step explanation:

answered
User Azquelt
by
8.6k points
5 votes

Step-by-step explanation:

Technique errors most commonly occur due to incorrect placement of the detector, wrong vertical or horizontal alignment of the X-ray beam, or collimator centering.

These errors can be avoided by placing the receptor relationship in alignment with the teeth so that the x-ray beam travels directly through the contact areas. This will place the receptor parallel to the buccal plane of the teeth of interest as well as the parallel to the instrument indicator ring.