asked 64.0k views
3 votes
What is the current of a 36,000W, 208V, Three-phase load?

2 Answers

3 votes
Let's calculate the current of a three-phase load with a power of 36,000W and a voltage of 208V.

To find the current, we can use the formula:

Current (A) = Power (W) / (√3 * Voltage (V) * Power Factor)

However, since the power factor is not provided, let's assume a power factor of 1 for simplicity.

Current (A) = 36,000W / (√3 * 208V * 1)

Now, let's calculate the current:

Current (A) = 36,000W / (√3 * 208V)
Current (A) ≈ 61.38A

Therefore, the approximate current of a 36,000W, 208V, three-phase load would be around 61.38 Amperes.
answered
User Andrei Todorut
by
8.0k points
3 votes
the current for a 36,000W, 208V, three-phase load (assuming a power factor of 1) is approximately 98.31 Amperes
answered
User Dwight Mendoza
by