asked 17.0k views
4 votes
For a very rough pipe wall the friction factor is constant at high Reynolds numbers. For a length L1 the pressure drop over the length is p1. If the length of the pipe is then doubled, what is the relation of the new pressure drop p2 to the original pressure drop p1 at the original mass flow rate?

asked
User Myluco
by
7.1k points

1 Answer

1 vote

Answer: ∆p2 = 2* ∆p1

Step-by-step explanation:

Given that all other factors remain constant. The pressure drop across the pipeline is directly proportional to the length.

i.e ∆p ~ L

Therefore,

∆p2/L2 = ∆p1/L1

Since L2 = 2 * L1

∆p2/2*L1 = ∆p1/L1

Eliminating L1 we have,

∆p2/2 = ∆p1

Multiplying both sides by 2

∆p2 = 2 * ∆p1

answered
User Murthy
by
8.4k points

Related questions

Welcome to Qamnty — a place to ask, share, and grow together. Join our community and get real answers from real people.